Sign In | Join Free | My disqueenfrance.com |
|
Brand Name : Chuangyin
Model Number : LZZBJ9-12A1
Certification : Kema, ISO, SGS, CE, TUV
Place of Origin : Shenzhen
MOQ : 1set
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 36,000,00pcs per year
Packaging Details : Plywood
Rated insulation level : 12/28/75 kv
Rated transformation ratio : 10-3150/5
Installation site : Indoor
Type : MV Current Transformer
Accuracy classes : 0.2/0.5 0.5/5P10
Frequency : 50/60HZ
Material : Epoxy Resin
Cast : Vacuum
TUV Proved 12kv MV Current Transformer with Single-Phase Epoxy Resin Casting Insulation
1.Product Introduction:
LZZBJ9-12A1(A2) current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omnidirectional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective relaying in the electrical system with the rated frequency 50- 60Hz and highest voltage for equipment 12 kV .
2. Technical Data:
1. Rated insulation voltage: 12/28/75kV etc.
2. Rated frequency: 50/60hz
3. Installation Site: Indoor
4. Standards: IEC60044-1(IEC61869-1&2)
3. Specification:
Rated transformation ratio(A) | Accuracy classes combination | Rated output(VA) | (ALF) | (FS) | Short-time thermal current Ith(kA/S) | Rated dynamic current Idyn(kA) | ||
Measuring | Protective | |||||||
0.2(S) | 0.5 | 10P | ||||||
10-200/5 | 0.2(S)/0.2(S) 0.2(S)/0.5 0.2(S)/10P 0.5/10P 0.2S/0.5/10P 0.2/0.5/10P | 10 15 | 15 | 15 | 10 15 20 | 5 (10) | 150I1n | 375I1n |
300/5 | 31.5 | 80 | ||||||
400/5 | 31.5 | 80 | ||||||
500/5 | 40 | 100 | ||||||
600/5 | 50 | 125 | ||||||
800/5 | 20 | 63 | 125 | |||||
1000/5 | 80 | 160 | ||||||
1200~1500/5 | 80 | 160 | ||||||
1500~2000/5 | 100 | 160 | ||||||
2000~3150/5 | 130 | 160 |
Rated transformation ratio(A) | Accuracy classes combination | Rated output(VA) | (ALF) | (FS) | Short-time thermal current Ith(kA/S) | Rated dynamic current Idyn(kA) | ||
Measuring | Protective | |||||||
0.2(S) | 0.5 | 10P | ||||||
10-200/5 |
0.2S//0.5/ 10P
0.5/0.5/10P | 10 15 | 15 |
15
20 |
10
15
| 5 (10) | 150I1n | 375I1n |
300/5 | 31.5 | 80 | ||||||
400/5 | 31.5 | 80 | ||||||
500/5 | 40 | 100 | ||||||
600/5 | 50 | 125 | ||||||
800/5 | 63 | 125 | ||||||
1000/5 | 80 | 160 | ||||||
1200~1500/5 | 80 | 160 | ||||||
1500~2000/5 | 100 | 160 | ||||||
2000~3150/5 | 130 | 160 |
4. Outline Drawing
5.Photos
![]() |
Light Weight Vacuum Resin Cast Current Transformer Fully Enclosed Images |